JavaScript is required

Operating Instructions of 3 Layers Fast Bottle Sterilizer and Dryer|BS01

1.Preparations before Operation

please refer to:Set-up and Use of 3 Layers Fast Bottle Sterilizer and Dryer|BS01

2.Method of Operation

2.1 Common (Bottle mode)

Place the cleaned bottles into the bottle chamber, place any cleaned nipples or baby dishes, knives, forks, spoons and other items into the upper tray, and close the top lid.

To power on the device, press the "On/Off" key,turn the knob to switch between "Common Mode" and "Breast Pump Mode".Press the "Confirm/Pause" key to select "Common Mode" when the "Common Mode" icon is flashing.

After entering Common Mode, you can turn the knob to choose "Sterilization", "Drying" or "Auto":

(1) Sterilization:Take 160 ml of pure water and add it to the base heating element. Turn the knob to "Sterilization"The "Sterilization" iconflashes. Press the "Confirm/Pause" keyfor sterilization. The "Sterilization" icon is ON. The digital screen displays "mm:ss" to indicate timing. For the sterilization process, the knob indicator lights up in blue. The operating time is 9 minutes. During the sterilization process, you can press "Confirm/Pause" key to pause the process in order to add additional items that need to be sterilized, and then press the "Confirm/Pause" keyto resume the sterilization process. After 9 minutes, the entire sterilization process ends. The sterilizer will beep 5 times and the digital screen and knob indicator will flash 5 times, to remind users that the "Sterilization" process has finished.

(2) Drying:It is not necessary to add pure water to the base heating element. When you turn the knob to "Drying", the digital screen displays a countdown timer set to 28 minutes by default.The "Drying" iconwill also flash. For this processyou can turn the knob to adjust the drying range from 10 minutes to 60 minutes. After adjusting the time, press the "Confirm/Pause" key to proceed with drying. The "Drying" iconis ON. The drying starts. The digital screen displays "mm:ss" to indicate countdown timing. For the drying process, the knob ring lights up in red. During this process, you can press "Confirm/Pause" keyto pause drying in order to add additional items that need to be dried, and then press the "Confirm/Pause" keyto resume the drying process. After the drying ends, the sterilizer will beep 5 times and the digital screen and knob indicator will flash 5 times, to remind users that the "Drying" process has finished.
(3) Auto:Take 160 ml of pure water and add it to the base heating element. When you turn the knob to "Auto", the digital screen countdown timer ("mm:ss") displays a countdown time of 37 minutes by default. The "Auto" icon will also flash.For this process , you can turn the knob to adjust the auto timing range from 19 minutes to 60 minutes (The sterilization time defaults to 9 minutes, and the adjustment is the drying time). After adjusting the time, press the "Confirm/Pause" keyto proceed with the Auto function.
The "Auto" icon is ON. The sterilization process starts first.The digital screen displays an operating time. For the sterilization process, the knob ring lights up in blue.After 9 minutes of sterilization, the sterilizer will automatically start the drying process. The digital screen will start the countdown according to the set drying time. For the drying process, the knob ring lights up in red.
Note:During this process, you can press "Confirm/Pause" keyto pause, add items that need to be sterilized and dried, and then press the "Confirm/Pause" keyto resume the Auto function.After the automatic operation ends, the sterilizer will beep 5 times and the digital screen and knob indicator will flash 5 times,to remind users that the "Auto" process has finished.

2.2 Breast pump parts mode

Rotate and fix the Breast pump to the bottle chamber, then place the cleaned electric breast pump parts or manual breast prump parts onto the breast pump post and parts rack, and close the top lid.
To power on the device, press the "On/Off" key,turn the knob to switch between "Bottle Mode" and "Breast Pump Mode".Press the "Confirm/Pause" keyto select "Breast Pump Mode"when the "Breast Pump Mode" icon is flashing.
After entering Breast Pump Mode, you can turn the knob to choose "Sterilization", "Drying" or "Auto".
(1) Sterilization: Take 160 ml of pure water and add it to the base heating element. Turn the knob to "Sterilization".The "Sterilization" iconflashes. Press the "Confirm/Pause" keyfor sterilization. The "Sterilization" iconis ON. The digital screen displays "mm:ss" to indicate timing. For the sterilization process, the knob ring lights up in blue. The operating time is 9 minutes. During the sterilization process, you can press "Confirm/Pause" key to pause the process in order to add additional items that need to be sterilized, and then press the "Confirm/Pause" keyto resume the sterilization process. After 9 minutes, the entire sterilization process ends. The sterilizer will beep 5 times and the digital screen and knob indicator will flash 5 times, to remind users that the "Sterilization" process has finished.
(2) Drying: It is not necessary to add pure water to the base heating element. When you turn the knob to "Drying", the digital screen displays a countdown timer set to 35 minutes by default.The "Drying" iconwill also flash. For this processyou can turn the knob to adjust the drying range from 10 minutes to 60 minutes. After adjusting the time, press the "Confirm/Pause"keyto proceed with drying.The "Drying" iconis ON.
The drying starts. The digital screen displays "mm:ss" to indicate countdown timing. For the drying process, the knob ring lights up in red. During this process, you can press "Confirm/Pause"keyto pause drying in order to add additional items that need to be dried, and then press the "Confirm/Pause" keyto resume the drying process. After the drying ends, the sterilizer will beep 5 times and the digital screen and knob indicator will flash 5 times, to remind users that the "Drying" process has finished.
(3) Auto: Take 160 ml of pure water and add it to the base heating element. When you turn the knob to "Auto",the digital screen countdown timer ("mm:ss") displays a countdown time of 44 minutes by default. The "Auto" icon (Auto)will also flash.For this process , you can turn the knob to adjust the auto timing range from 19 minutes to 60 minutes (The sterilization time defaults to 9 minutes, and the adjustment is the drying time). After adjusting the time, press the "Confirm/Pause" keyto proceed with the Auto function.
The "Auto" icon is ON. The sterilization process starts first.The digital screen displays an operating time. For the sterilization process, the knob ring lights up in blue.
During this process, you can press "Confirm/Pause" keyto pause, add items that need to be sterilized and dried, and then press the "Confirm/Pause" keyto resume the Auto function.After the automatic operation ends, the sterilizer will beep 5 times and the digital screen and knob indicator will flash 5 times,to remind users that the "Auto" process has finished.
 

2.3 Storage

(1) Auto storage mode:When selecting the "Auto"or "Dry" function under any of "Common Mode"or "Breast Pump Mode",the "Storage" icon flashes, you can skip it to start the process so that the unit can automatically enter 24 hours storage mode after "Auto"or "Dry"finished. The unit will start the drying process for 5 minutes for each 1 hour to keep the inner chamber dry. Or you can also press "Storage" icon to light it out before you start the process so that to cancel auto storage after "Auto"or "Dry" finished.

(2) Manual storage mode(Storage only, without sterilization or drying or Auto process). Plug in the device by pressing "On/Off"key, turn the knob to switch between any of "Common Mode"or "Breast Pump Mode",press "Storage" icon and then press "Confirm/Pause" key to start 24 hours "storage only" process, the unit will start the drying process for 5 minutees for each 1 hour to keep the inner chamber dry.