Cleanliness of pump components directly prevents bacterial contamination of breast milk and protects infant health. Follow these rules before first use and after every pumping session:
• Wash all milk-contact parts thoroughly before first use and after each pumping session.
• The main pump motor unit contains electrical components. Never immerse it in water or any liquid. Wipe the exterior only with a soft, slightly damp cloth, then dry immediately.
• Tubing does not come into contact with breast milk under normal operation. If milk enters the tubing, disconnect and replace it. Do not wash or reuse a tube that has milk.
• Do not use abrasive cleaners, bleach, or antibacterial chemicals on any parts.
• Inspect all silicone and plastic parts before each use for cracks, tears, discoloration, or aging. Replace damaged parts immediately.
• Pre-clean preparation step: Scrub hands thoroughly with soap and running water for a full 20 seconds before disassembling or handling pump components.How to disassembly the pump,please refer to:Disassembly and Installation of V3 Breast Pump
1.Disinfect Milk-Contact Parts
All milk-contact silicone/ plastic pieces require hand washing only; dishwasher safety has not been verified for this device.
Step 1: Hand Washing
Required supplies: Baby-safe dish soap, drinking-quality warm water, dedicated infant cleaning basin, soft bottle brush, lint-free paper towels.
-
Rinse disassembled parts under running warm/cold water immediately after pumping to dissolve residual milk (do not let milk dry onto surfaces).
-
Place all pieces into a dedicated baby cleaning basin (do not wash directly in kitchen sink drains, which harbor bacteria).
- Soak components in 40–60°C (104–140°F) soapy water for 3–5 minutes.
- Scrub all inner and outer surfaces completely with a soft baby bottle brush.
- Rinse thoroughly under clean running drinking water until no soap residue remains.
-
Lay all parts flat on unused paper towels in a dust-free, dry area to air-dry fully. Do not rub dry with cloth towels (fabric transfers bacteria).
- Clean the wash basin and brush after every use. For infants under 3 months, premature babies, or immunocompromised infants, sanitize the basin / brush after each wash cycle.
WARNING
Do not use abrasive scrubbers or antibacterial cleaners — these damage silicone and leave toxic residue in contact with breast milk.
Step 2: Disinfection (Required at least once daily)
CAUTION
Boiling water disinfection is the only approved method for this pump’s milk-contact components. Microwave and UV sterilizers will deform silicone parts and shorten service life.DO NOT MICROWAVE.
- Fill a clean household pot with enough drinking water to fully submerge all disassembled parts.
- Place components in the pot, ensuring no silicone/plastic pieces touch the hot metal pot walls.
- Bring water to a rolling boil and maintain boiling for 5–10 minutes.
- Remove sanitized parts using clean tongs only.
- Lay flat on paper towels to air-dry completely before storage.
Step 3: Dry Storage
1. Confirm all components are 100% air-dried (moisture causes mold and bacterial growth).
2. Wash hands with soap before reassembling dry parts.
3. Store fully assembled clean pump sets inside a closed, dust-free kitchen cabinet reserved exclusively for infant feeding supplies.
2.Wipe Down Non-Milk Components
• Main pump motor unit: Wipe with a soft, dry or slightly damp cloth. Do not allow liquid to enter the tubing ports.
• Power adapter: Wipe with a dry cloth only. Ensure the adapter is unplugged and fully dry before use.
• Tubing: Wipe exterior with a dry cloth. Do not wash the interior. Replace if milk enters or if the tubing becomes cracked, deformed, or discolored.
Supplies Needed:70% isopropyl alcohol wipes, soft lint-free cloth
Surface Cleaning Process
- Wash and sanitize your hands first.
- Wipe away all visible milk residue or dirt on the motor housing with a dry soft cloth.
- Swab all exterior surfaces with 70% alcohol wipes until no stains remain.
- Leave the unit at room temperature for 10 minutes to fully evaporate alcohol residue before use.
Deep Disinfection Wipe
- Complete the surface cleaning steps above.
- Dampen a soft cloth with 70% isopropanol and gently wipe the motor shell for 3 full minutes.
- Air-dry at room temperature for 10 minutes to eliminate all alcohol residue.